DiamCalc download
GemAdviser download
Rapaport price list converter
 
Oxygen Viewer Free Version download
Oxygen Microscope Server download
Oxygen Inclusion download
Oxygen XRay download
 
Helium Rough download
Helium Rough templates of reports
Helium Rough buttons
 
Helium Polish download
Helium Polish templates of reports
Helium Polish buttons
 
Pacor Client download
 
External Cut modules download
 
Set of Optimization Algorithms for Helium Rough & Pacor Client
 
Cut Quality Appraisers download
External Symmetry Appraiser download
 
DiamCalc Documentation
DiamCalc Howto..
Oxygen Inclusion documentation
Helium Polish Highlights
Helium Polish system manual
Helium reports documentation
 
The Gallery
DiamCalc scenarios
Rough and Polish diamond movies
Collection of different parametrical diamond models with IdealScope lighting
3DCalc demo .gem files
 
Download the Algorithms for HR & PC

Set of Optimization Algorithms

All algorithms are improved. Added new 08.Single and 08.Single.Flex

These algorithms work with programs since version 4.37

Method2002.zip (4,79 Kb) - The package contains algorithms for Helium Rough and Pacor Client with updates from 15 december, 2008

Installation instuctions

1. Download and replace file Method2002.Mmd with new one from the downloaded archive Method2002.zip. You can find current version of the file Method2002.Mmd in the root folder of the program Helium Rough or Pacor Client. The default path is C:\Program Files\OctoNus Software\Helium

2. Run program. In the panel Marking out press on the cross and select Load default methods (Method2002.mmd). Then save current project as Heliumstart.mmd (for Helium Rough) or Start.mmd (for Pacor Client) - in the main menu select Start/Save project as.. and find in the default folder given files. Check before that files Heliumstart.mmd or Start.mmd are not read-only in the properties of files (the default path for location of files: C:\Program Files\OctoNus Software\Helium or C:\Program Files\OctoNus Software\Pacor-client)

3. Next time program will get new set of algorithms

Note

To open mmd-file created with early versions of algorithms (file Method2002.mmd) and run optimization with one of the new algortihms:

  1. Open file
  2. In the panel Marking out press on the cross and select Load default methods (Method2002.mmd)
  3. In the panel Marking out on the page Process, section Optimize right click on the algorithm and select required new algorithm
  4. Run optimization

More details...