Helium Rough download

Helium Rough 6.0 build 45

Description

The software Helium Rough works with Helium Rough and Helium Tender scanners.
  
Helium Rough is the most accurate advanced rough cavity mapping and inclusion scanning, value based planning equipment, optimizing rough with value analysis and sawing plans.. 
Helium Tender is a portable scanner. 

Make sure that you saved all previous files of Helium Rough program before downloading and installation of new program in store archive folder. In case of necessity you can use them. 

What is new in the Helium Rough ?

InstallHeliumRough-6.0.45.exe (44 Mb) - Helium Rough version 6.0 build 45 (22 December, 2015)

Read this carefully before installation

The distributives for for Helium Rough and Pacor Client are available now. 

Main program and main components that are not recommended to be edited by user and can be edited only by Lexus/OctoNus will be unpacked to system folder:

  • for Pacor Client:
    C:\Program Files (x86)\OctoNus Software\Pacor Client 6
  • for Helium Rough:
    C:\Program Files\OctoNus Software\HeliumRough 6

Components which are open for user edit will be unpacked to data folder:

  • for Pacor Client
    %ProgramData%\OctoNus Software\PacorClient
  • for Helium Rough
    %ProgramData%\OctoNus Software\HeliumRough

usually %ProgramData% is C:\ProgramData\... 

In this folder PacorBatLocal.ini or HeliumBatLocal.ini could be written load of any user appraisers, pricelists, reports. 

Reports and cuttings will be loaded from folders Cuttings and Reportboth from system folder and from data folder. 

For Helium Rough for upgrade from previous version to new one it is necessary to copy (this should be only once and will not be required ion future versions):

  • HeliumSystem.bin to data folder %ProgramData%\Octonus Software\HeliumRough
  • HeliumStart.mmd to data folder %ProgramData%\Octonus Software\HeliumRough
  • HeliumDrivers.ini to data folder %ProgramData%\Octonus Software\HeliumRough
  • files _Zoom3.bmp and _GridZoom3.bmp to subfolder System of data folder %ProgramData%\Octonus Software\Helium Rough 6\System

If there were tuned other modes, like half-resolution mode or others, then it is necessary to copy others files like _Zoom...bmp or _GridZoom...bmp 

If client used non-standard reports or cuttings then it is necessary to put them in data folder. 
If client used non-standard pricelists and appraisers then it is necessary to put them in data folder and write their load in HeliumBatLocal.ini, located in data folder. 

There are two files since this version - HeliumBat.ini in system folder and HeliumBatLocal.ini in data folder. File HeliumBat.ini is prohibited to edit, but in file HeliumBatLocal.ini it is required to move all non-standard, customized for each client, settings which were in HeliumBat.ini before. As usual, it is CopyCuttingLoadCCFAppraiserLoadParsAppraiserLoadExternalGrading for custom cuttings, appraisers and pricelists.